AIRPURION 2001 / 4

...is characterized by an extraordinarily high disinfection performance with a compact design and low energy consumption. It is designed in accordance with applicable laws, standards and directives.

Airpurion_2001_4

The AIRPURION 2001 /4 consists of four PURION 2001 reactors that must be installed in series. The introduced air is passed through the reactors and disinfected. The unit can be easily integrated into pipeline systems, even retroactively.

The system can optionally be equipped with lifetime monitoring (OTC – Operating Time Counter) with potential-free contacts.

The control unit is integrated into an electrical cabinet, which can optionally be made of stainless steel. The electrical cabinet is standardly equipped with a “total signal error message.” In case of a UV system failure, a red indicator light on the cabinet door will illuminate, and at the same time, this error can be externally evaluated (potential-free contact). The function of each UV lamp is indicated by a green indicator light.

The compact design allows for easy and tool-free lamp removal and replacement, for example, at the end of the emitter’s useful life.

Optionally, the PURION 2001 /4 duct unit can be equipped with the PURION mounting set AIRPURION 2001 – 2501. This enables easy and space-saving wall mounting if needed.

Technical Specifications

ManufacturerPURION GmbH
TypeAIRPURION 2001/4
Disinfection performance 99%up to 120 m³/h air
Dimensions H x W x D in mm:
Reactor control cabinet H x W x D :
578 x 372 x 85
600 x 600 x 210
Number of reactors4 x PURION 2001
External thread connectionR 1 1/2“
Max temperature60°C / 90°C
Lamp lifetime8,000 - 10,000 hours
Number of lamps4
Housing protection classIP 54
Electrical connection3 ~/N/PE
50 Hz 400/230V
Power4 x 48 W (up to 60°C)
4 x 42 W (up to 90°C)
Fusing3 x 6A

Details on Disinfection Performance:

 
Max. air volume
 
Guaranteed
UVC Dose1
60% humidity90% humidity
30 J/m²120 m³/h70 m³/h
90 J/m²40 m³/h24 m³/h

This system is used for:

Air disinfection in the beverage industry
Chemical industry with organic materials/process chemicals
Ventilation concepts for cleanroom industries

Advantages: 

  • No chemical input
  • No odor or taste interference
  • Low maintenance operation
  • Low operating costs

Download data sheet

DATASHEET AIRPURION 2001 4

1Adose of 30 J/m² ensures 99% disinfection for light to medium contamination, e.g. by Ecoli, Salmonella; a dose of 90 J/m² ensures 99% disinfection for medium to high contamination, e.g. by influenza viruses, brown yeast and listeria.