Air

AIRPURION 2001 / 2

...is characterized by an extraordinarily high disinfection performance with a compact design and low energy consumption. It is designed in accordance with applicable laws, standards and directives.

Airpurion_2001_2

The AIRPURION 2001 /2 consists of two PURION 2001 reactors which must be installed in series. The introduced air is passed through the reactors and disinfected. The unit can be easily integrated into pipeline systems, even retroactively.

The system can optionally be equipped with a lifetime monitoring (OTC – Operating Time Counter) with potential-free contacts.

The control unit is integrated into an electrical cabinet, which can optionally be made of stainless steel. The electrical cabinet is standardly equipped with a “total signal error message.” In case of a UV system failure, a red indicator light on the cabinet door will illuminate, and at the same time, this error can be externally evaluated (potential-free contact). The function of each UV lamp is indicated by a green indicator light.

The compact design allows for easy and tool-free lamp removal and replacement, for example, at the end of the emitter’s useful life.

Optionally, the PURION 2001 /2 duct unit can be equipped with the PURION mounting set AIRPURION 2001 – 2501. This enables easy and space-saving wall mounting if needed.

Technical Data

ManufacturerPURION GmbH
TypeAIRPURION 2001/2
Disinfection Performance 99%up to 60 m³/h air
Dimensions H x W x D in mm:
Reactor Control Cabinet H x W x D:
578 x 186 x 85
600 x 600 x 210
Number of Reactors2 x PURION 2001
External Thread ConnectionR 1 1/2“
Max Temperature60°C / 90°C
Lamp Lifetime8,000 - 10,000 h
Number of Lamps2
Enclosure Protection RatingIP 54
Electrical ConnectionL/N/PE 50 Hz 230V
Power2 x 48 W (up to 60°C)
2 x 42 W (up to 90°C)
Fuse1 x 6A

Disinfection Performance Details:

 
Max Air Volume
 
Guaranteed
UVC Dose1
60% Humidity90% Humidity
30 J/m²60 m³/h35 m³/h
90 J/m²20 m³/h12 m³/h


This device is used for:

Air Disinfection Beverage Industry
Chemical Industry with Organic Materials/Operating Materials
Ventilation Concepts for Cleanroom Industry

Advantages: 

  • No chemical input
  • No odor or taste alteration
  • Low maintenance operation
  • Low operating costs

Download Datasheet

DATASHEET AIRPURION 2001 2

1Adose of 30 J/m² ensures 99% disinfection for light to medium contamination, e.g. by Ecoli, Salmonella; a dose of 90 J/m² ensures 99% disinfection for medium to high contamination, e.g. by influenza viruses, brown yeast and listeria.


Further product portfolio