Air

AIRPURION 2501 / 4

...is characterized by an extraordinarily high disinfection performance with a compact design and low energy consumption. It is designed in accordance with applicable laws, standards and directives.

Airpurion_2501_4

The AIRPURION 2501 /4 consists of four PURION 2501 reactors which must be installed in series. The incoming air is passed through the reactors and disinfected. The unit can be easily integrated into pipeline systems, even retroactively.

The system can optionally be equipped with a lifetime monitoring (OTC – Operating Time Counter) with potential-free contacts.

The control system is integrated into a control cabinet, which can optionally be made of stainless steel. The control cabinet is standardly equipped with a "total signal error message". In case of a UV system failure, a red indicator light on the control cabinet door lights up, and the error can also be externally monitored (potential-free contact). The function of each UV lamp is displayed by a green indicator light.

The compact design allows for easy, tool-free removal and replacement of the lamps, for example, at the end of their service life.

Optionally, the PURION 2501 /4 duct unit can be equipped with the PURION mounting kit AIRPURION 2001 – 2501. This allows for easy and space-saving wall mounting if required.

Technical Specifications

ManufacturerPURION GmbH
TypeAIRPURION 2501/4
Disinfection Efficiency 99%up to 200 m³/h air
Dimensions H x W x D in mm:
Reactors Control Cabinet H x W x D :
928 x 372 x 85
600 x 600 x 210
Number of Reactors4 x PURION 2501
External Thread ConnectionR 1 1/2“
Max Temperature60°C / 90°C
Lamp Lifetime8,000 - 10,000 hours
Number of Lamps4
Enclosure Protection ClassIP 54
Electrical Connection3 ~/N/PE
50 Hz 400/230V
Power4 x 90W (up to 60°C)
4 x 106W (up to 90°C)
Fuse Protection3 x 6A or 3 x 10A

Disinfection Performance Details:

 
Max Airflow
 
Guaranteed
UVC Dose1
60% Humidity90% Humidity
30 J/m²200 m³/h120 m³/h
90 J/m²70 m³/h40 m³/h

This system is used in:

Air Disinfection in the Beverage Industry
Chemical Industry with Organic Materials / Operating Fluids
Ventilation Concepts for Cleanroom Industries

Advantages: 

  • No chemical contamination
  • No odor or taste alteration
  • Low maintenance operation
  • Low operating costs

Download Data Sheet

DATA SHEET AIRPURION 2501 4

1Adose of 30 J/m² ensures 99% disinfection for light to medium contamination, e.g. by Ecoli, Salmonella; a dose of 90 J/m² ensures 99% disinfection for medium to high contamination, e.g. by influenza viruses, brown yeast and listeria.