AIRPURION 2501 / 6
...is characterized by an extraordinarily high disinfection performance with a compact design and low energy consumption. It is designed in accordance with applicable laws, standards and directives.
The AIRPURION 2501 /6 consists of six PURION 2501 reactors which must be installed in series. The incoming air is passed through the reactors and disinfected. The unit can be easily integrated into pipeline systems, even retroactively.
The system can optionally be equipped with a lifetime monitoring (OTC – Operating Time Counter) with potential-free contacts.
The control system is integrated into a control cabinet, which can optionally be made of stainless steel. The control cabinet is standardly equipped with a "total signal error message". In case of a UV system failure, a red indicator light on the control cabinet door lights up, and the error can also be externally monitored (potential-free contact). The function of each UV lamp is displayed by a green indicator light.
The compact design allows for easy, tool-free removal and replacement of the lamps, for example, at the end of their service life.
Optionally, the PURION 2501 /6 duct unit can be equipped with the PURION mounting kit AIRPURION 2001 – 2501. This allows for easy and space-saving wall mounting if required.
Technical Data
Manufacturer | PURION GmbH |
Type | AIRPURION 2501/6 |
Disinfection Efficiency 99% | up to 300 m³/h air |
Dimensions H x W x D in mm: Reactors / Control Cabinet H x W x D : | 928 x 558 x 85 600 x 600 x 210 |
Number of Reactors | 6 x PURION 2501 |
External Thread Connection | R 1 1/2“ |
Max. Temperature | 60 °C / 90 °C |
Lamp Lifetime | 8,000 - 10,000 h |
Number of Lamps | 6 |
Enclosure Protection Rating | IP 54 |
Electrical Connection | 3 ~/N/PE 50 Hz 400/230V |
Power | 6 x 90W (up to 60 °C) 6 x 106W (up to 90 °C) |
Circuit Protection | 3 x 6A or 3 x 10A |
Details of the Disinfection Performance:
max. Air Volume | ||
guaranteed UVC Dose1 | 60% Relative Humidity | 90% Relative Humidity |
30 J/m² | 300 m³/h | 180 m³/h |
90 J/m² | 100 m³/h | 60 m³/h |
This System is Used In:
Air Disinfection in the Beverage Industry |
Chemical Industry with Organic Materials/Substances |
Ventilation Systems for the Cleanroom Industry |
Advantages:
- No chemical additives
- No impact on odor and taste
- Low maintenance operation
- Low operating costs
Download Datasheet
1Adose of 30 J/m² ensures 99% disinfection for light to medium contamination, e.g. by Ecoli, Salmonella; a dose of 90 J/m² ensures 99% disinfection for medium to high contamination, e.g. by influenza viruses, brown yeast and listeria.
Further product portfolio
-
-
The PURION mounting systems enable space-saving and safe installation
-
Targeted UV-based air disinfection in ventilation and air conditioning systems